Exploring the relative efficacy of motion artefact correction techniques for EEG data acquired during simultaneous fMRI

Alexander J. Daniel, G Spencer, Karen Mullinger

Research output: Contribution to journalArticlepeer-review

121 Downloads (Pure)

Abstract

Simultaneous EEG-fMRI allows multi-parametric characterisation of brain function, in principle enabling a more complete understanding of brain responses; unfortunately the hostile MRI environment severely reduces EEG data quality. Simply eliminating data segments containing gross motion artefacts [MAs] (generated by movement of the EEG system and head in the MRI scanner’s static magnetic field) was previously believed sufficient. However recently the importance of removal of all MAs has been highlighted and new methods developed.
A systematic comparison of the ability to remove MAs and retain underlying neuronal activity using different methods of MA detection and post-processing algorithms is needed to guide the neuroscience community. Using a head phantom, we recorded MAs while simultaneously monitoring the motion using three different approaches: Reference Layer Artefact Subtraction (RLAS), Moiré Phase Tracker (MPT) markers, and Wire Loop Motion Sensors (WLMS). These EEG recordings were combined with EEG responses to simple visual tasks acquired on a subject outside the MRI environment. MAs were then corrected using the motion information collected with each of the methods combined with different analysis pipelines.
All tested methods retained the neuronal signal. However, often the MA was not removed sufficiently to allow accurate detection of the underlying neuronal signal. We show that the MA is best corrected using the RLAS combined with post-processing using a multi-channel, recursive least squares (M-RLS) algorithm. This method needs to be developed further to enable practical utility; thus, WLMS combined with M-RLS currently provides the best compromise between EEG data quality and practicalities of motion detection.
Original languageEnglish
Article numberHBM-18-0228.R2
JournalHuman Brain Mapping
Volume40
Issue number2
Early online date19 Oct 2018
DOIs
Publication statusE-pub ahead of print - 19 Oct 2018

Keywords

  • head motion artefact
  • simultaneous EEG-fMRI
  • motion artefact detection
  • artefact correction
  • quantitative comparison

Fingerprint

Dive into the research topics of 'Exploring the relative efficacy of motion artefact correction techniques for EEG data acquired during simultaneous fMRI'. Together they form a unique fingerprint.

Cite this